BugZero updated this defect 58 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
3/22/2024
Smart Assurance - SMARTS
No affected releases provided.
No fixed releases provided.
Smarts SAM is missing notifications from underlying Smarts OI domain after recent upgrade from Smarts SAM 7.1 to 7.2 Smarts SAM reports SNMP Traps event with Last Notify and First Notify set to "never"
The above symptoms have been seen when there is an uninitialized variable error in the ics-nl-processing.asl script.
Initializing the variable gets around the problems with the SNMP trap. To edit the ics-nl-processing.asl script and initialize the variable, do the following:Open the ics-nl-processing.asl script for editing using Smarts sm_edit as follows:<BASEDIR>/smarts/bin/sm_edit ../rules/ics/ics-nl-processing.asl Initialize the inName variable around Line 727 as in the following example: UPDATE_EVENT_OBJECT { local elementName; local displayName; local additionalAttributesChanged = FALSE; local isChanged = FALSE; local shouldNotify = FALSE; local isActive = FALSE; local remoteEventObj = object(); local eventClass; local impact; local field; local value; local delta_count = 0; local i = 1; local inName = ""; //<- add this lineRestart the Smarts SAM domain to apply the changes.