Operational Defect Database

BugZero updated this defect 33 days ago.

VMware | 363448

Loading Smarts SAM configuration changes without restarting the server.

Last update date:

4/16/2024

Affected products:

Smart Assurance - SMARTS

Affected releases:

No affected releases provided.

Fixed releases:

No fixed releases provided.

Description:

Symptoms

How to load SAM configuration changes without restarting the server.How to make changes in ics.conf effective.

Resolution

From the command line, run the following command:<basedir>/SAM/smarts/bin/sm_adapter -s <global_manager> ics/ICS_RemoteConfig.asl Information on this command can be found in <basedir>/SAM/smarts/doc/pdf/sm_config.pdf. Section on "Reconfiguring the Global Manager"

Related Information

There must be a change in ics.conf in order for Remote Config to take affect. if ics.conf is not modified, running Remote Config will not make any change either. A quick change can be changing SmoothingInterval from 65 to 64. Example: <BASEDIR>/SAM/smarts/bin/sm_edit conf/ics/ics.conf Change: SmothingInterval = 65; to: SmoothingInterval = 64;

Additional Resources / Links