BugZero updated this defect 58 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
3/22/2024
Smart Assurance - SMARTS
No affected releases provided.
No fixed releases provided.
Previously managed or unmanaged ports are not reflecting their updated managed state after a discovery Newly activated switch ports are not showing as managed when they were previously unmanaged
The managed state will not change after discovering the ports of a switch if the user has explicitly managed or unmanaged the port.
In the GUI, Smarts will see the IsManaged attribute of objects but has no way to know whether the state was explicitly changed by the user or is changed by the discovery process. To get some detail of the managed state, you need to run the following command:Example, you want to find the managed state of the switch "tetrahedron.smarts.com":dmctl -s <server name> invoke Switch::tetrahedron.smarts.comgetManagedState This command will return one of the four enumerations: MANAGED, EXPLICITLY_MANAGED, UNMANAGED, EXPLICITLY_UNMANAGED