Interface NotPresent notifications for some interfaces on Cisco 7206.
From IP debug discovery logs, the following can be seen from the SNMP trace output while querying the interface admin status : 121: VarBind -> SEQUENCE (0x30), 14 bytes: 123: OBJ-ID (0x06), 10 bytes == ".1.3.6.1.2.1.2.2.1.7.102" 135: Exception (IMPLICIT NULL) (0x81), 0 bytes == <noSuchInstance> 137: VarBind -> SEQUENCE (0x30), 14 bytes: 139: OBJ-ID (0x06), 10 bytes == ".1.3.6.1.2.1.2.2.1.8.102" 151: Exception (IMPLICIT NULL) (0x81), 0 bytes == <noSuchInstance>
This is a vendor agent issue. The response above is an invalid agent response, which means that Smarts cannot determine the admin or operating status of an interface, and as a result, reports that the status is NOTPRESENT.