Smarts IP reporting interface NotPresent events from Cisco 7206

Last update date:

4/16/2024

Affected products:

Smart Assurance - SMARTS

Affected releases:

No affected releases provided.

Fixed releases:

No fixed releases provided.

Description:

Symptoms

Interface NotPresent notifications for some interfaces on Cisco 7206.

Cause

From IP debug discovery logs, the following can be seen from the SNMP trace output while querying the interface admin status : 121: VarBind -> SEQUENCE (0x30), 14 bytes: 123: OBJ-ID (0x06), 10 bytes == ".1.3.6.1.2.1.2.2.1.7.102" 135: Exception (IMPLICIT NULL) (0x81), 0 bytes == <noSuchInstance> 137: VarBind -> SEQUENCE (0x30), 14 bytes: 139: OBJ-ID (0x06), 10 bytes == ".1.3.6.1.2.1.2.2.1.8.102" 151: Exception (IMPLICIT NULL) (0x81), 0 bytes == <noSuchInstance>

Resolution

This is a vendor agent issue. The response above is an invalid agent response, which means that Smarts cannot determine the admin or operating status of an interface, and as a result, reports that the status is NOTPRESENT.