3/22/2024
Smart Assurance - NCM
No affected releases provided.
No fixed releases provided.
After re-deployment of Smarts Network Configuration Manager (Smarts NCM) device server, the commgrd process keeps restartingAfter redeployment of a Smarts NCM Device server, the commmgrd process keeps restarting after bringing up servicescommmgrd Process ID (PID) keeps changing on Smarts NCM device server as seen in the commmgr.logSmarts NCM Jobs are not resumed or are not being processed properly after a Smarts NCM device server redeployment
After redeployment of the Smarts NCM device server, the commmgrd service is unable to properly process acmd files. This is because when a Smarts NCM device server restarts, it looks for pending previous jobs in acmd files and starts executing them, and the commmgrd service is unable to process one or more of these files.
If you encounter this issue, do the following: Delete all acmd files found in the following folder on the Smarts NCM Application server: VOYENCE_HOME/data/appserver/pops/pop1000/syssync/commmgr/toMaster/deviceupdate Install/start the re-deployed Smarts NCM Device server.Once communication between the Smarts NCM Application server and Device server is verified and the all processes on the Device server are stable with no constant restarting processes, jobs previously queued may need to be cancelled and run manually at a later time.