3/22/2024
Smart Assurance - SMARTS
No affected releases provided.
No fixed releases provided.
Ionix/Smarts Network Protocol Management (NPM) application cannot discover Border Gateway Protocol (BGP) session objects BGP Sessions similar to the following are found from the SNMP walk:.1.3.6.1.2.1.15.3.1.5.213.1.79.80: 213.1.79.81 .1.3.6.1.2.1.15.3.1.5.213.1.79.126: 213.1.79.125 .1.3.6.1.2.1.15.3.1.5.213.1.79.138: 213.1.79.137 .1.3.6.1.2.1.15.3.1.5.213.1.79.154: 0.0.0.0 .1.3.6.1.2.1.15.3.1.5.213.1.79.158: 0.0.0.0 BGP session objects are not discovered for Cisco device from Ionix/Smarts NPM
Ionix/Smarts NPM will not display a BGP session with a end point of 0.0.0.0. An IP address of 0.0.0.0 indicates a TCP/IP network cannot be reached. Having this address, a computer cannot be reached or communicate with any other devices over an IP network.
To resolve this issue, ensure the correct session (endpoints) are on the device. Once this has been done, apply the fix described in 54151 .