Operational Defect Database

BugZero updated this defect 33 days ago.

VMware | 380457

Smarts IP-AM: Does the "DefaultMaximumNetworkSizeForCorrelation" parameter ever create a new root cause?

Last update date:

4/16/2024

Affected products:

Smart Assurance - SMARTS

Affected releases:

No affected releases provided.

Fixed releases:

No fixed releases provided.

Description:

Symptoms

Does the Smarts DefaultMaximumNetworkSizeForCorrelation parameter ever create a new root cause?

Resolution

No, the DefaultMaximumNetworkSizeForCorrelation parameter never creates a new Root Cause in Smarts. This is because it is an additional parameter meant to limit the CodeBook size alone for the connected networks. The MaximumNetworkSizeForCorrelation parameter (whose default value is set to 10) will eventually reduce the CodeBook size to avoid "Out Of Memory" crashes and also to effectively reduce the symptom set for a DOWN computation for a UCS (Unitary Computer System).