Smart Assurance - SMARTS
No affected releases provided.
No fixed releases provided.
Smarts IP does not discover switch ports for Cisco 6506 switch Smarts IP discovery fails for Cisco 6506 switch ports and CiscoStack MIBs (.1.3.6.1.4.1.9.5.1 in the following Stack Certification) for the ports are not found in the SNMP walk, snap or mimic Driver:Cisco-Stack-Driver ReadRulesFrom:discovery/ic-cisco-stack.asl OIDs:.1.3.6.1.4.1.9.5.1.2.16 OIDs:.1.3.6.1.4.1.9.5.1.2.19 OIDs:.1.3.6.1.4.1.9.5.1.3.1.1.21 OIDs:.1.3.6.1.4.1.9.5.1.3.1.1.17 OIDs:.1.3.6.1.4.1.9.5.1.3.1.1.2 OIDs:.1.3.6.1.4.1.9.5.1.3.1.1.
The Cisco Stack MIB is required to discover all port information.
Load the required Cisco stack MIB according to the following certification for the switch (IP/smarts/conf/discovery/oid2type_Cisco.conf): 379 .1.3.6.1.4.1.9.1.282 {380 TYPE = Switch381 VENDOR = Cisco382 MODEL = 6506383 CERTIFICATION = CERTIFIED384 CONT = Cisco-L3Stack385 VLAN = Cisco-Membership386 BRIDGE = Cisco387 NEIGHBOR = Cisco-Stack388 HEALTH = Cisco-Stack