Description:

Symptoms

Remote Voyence commands not working if IOS privilege level 15 is requiredSome remote commands report "% Invalid input detected at '^' marker"Cisco IOS privilege level is 15 and in enable mode >>> output >>>show runshow run^% Invalid input detected at '^' marker. uk-run-NGWAN-R2><<< output <<<

Cause

This is a security feature introduced several releases ago to disallow migrating a session to user level ('disable') if there is no privilege password defined. Cisco devices have a default non-privilege mode prompt ending in '>'. This device does not: '#' indicates what NCM considers privilege mode. The incoming command is defined to be issued in user mode, so the code is migrating the session from privilege to user mode, and first checking if there is a privilege password defined in the event it needs to return in subsequent operations.If the account has been created at above default privilege, then a privilege password for the device in NCM must be defined or the attempt to go to user/disable mode will fail before the command is ever issued.

Resolution

Product is working as designed. An Enhancement Request is required to revise the behaviour of the product in this scenario.