Description:

Symptoms

Watch4net APG 5: Activating the Smarts performance data collection on VLAN interfaces (PROPVIRTUAL)How to activate the Smarts performance data collection on VLAN interfaces (PROPVIRTUAL) in Watch4Net APG 5

Resolution

The Smarts IP/local/rules/health/adapter-setting.asl file must be modified with the following changes: // if (!obj->IsManaged ||// sizeof(obj->LayeredOver) > 0 && subIfPerfMode == disabledMode ||// glob("*Vlan*", obj->Description) || thrSettingObj->isNull()) {// REMOVE_PERF_INSTRUMENTATION(obj);// continue;// }// Now: if (!obj->IsManaged || sizeof(obj->LayeredOver) > 0 && subIfPerfMode == disabledMode || thrSettingObj->isNull()) { REMOVE_PERF_INSTRUMENTATION(obj); continue; } Restart the Smarts PM process after making the above changes.