BugZero updated this defect 58 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
3/22/2024
Smart Assurance - Watch4net/M&R
No affected releases provided.
No fixed releases provided.
How to display model name instead of OID number for an unknown model in EMC M&R and ViPR SRM
This is done easily by modifying the allOid2ModelsFor Cisco devices you must update ptf-mds3.xml which will update allOid2Models-mds.csv upon collector-manager restart File are located under: UNIX/Linux: /opt/APG/Collecting/Mapped-Property-Tagged-Filter/<INSTANCE>/conf/ Windows: C:\Program Files\APG\Collecting\Mapped-Property-Tagged-Filter\<INSTANCE>\conf\ Equipment NameIP AddressModelDescriptionMediantxx.xxx.xxx.xxx1.3.6.1.4.1.5003.8.1.1.47Product: MG 1K;SW... The format of this file is very simple (TAB is used as the delimiter): model_oid model_name Here is an abstract of this file: .1.3.6.1.4.1.43.1.8.29 SuperStackII Desktop Switch SW Version:2.10.1.3.6.1.4.1.43.10.27.4.1.2.1 3Com SuperStackII.1.3.6.1.4.1.43.1.8.24 SuperStack II Switch.1.3.6.1.4.1.43.1.13.1 SuperStackII Advanced RPS.1.3.6.1.4.1.135.28 AccessBuilder 6218-JX[...] Restart the collector manager.
After adding the missing OID and model number to ptf-mds3.xml, and restarting the Cisco MDS collector manager, the reports would display both OID and model number under Model. The allOid2Models file also had to be modified to add OID and model number:ptf-mds3.xml:<parameter name="line">.1.3.6.1.4.1.9.12.3.1.3.843,MDS DS-HP-8GFC</parameter> allOid2Models:.1.3.6.1.4.1.9.12.3.1.3.843 MDS DS-HP-8GFC After the above modifications, the switch Model displays the correct model number.