Description:

Symptoms

This article explains how to use the "parsing-tester.sh" text collector parser test tool, and how to address the issue when CSV parsing is not working for blank values.

Resolution

The "parsing-tester.sh" utility is available in /opt/APG/Collecting/Text-Collector/Default/bin for testing the XML parser config when creating text parser xml. The documentation for setting up text parser filter is found in APG-Text-Parsing-Library.pdf, which is installed with the Watch4net software in the /opt/APG/Collecting/Text-Collector/doc directory. To address the issue of CSV parsing failing for blank values, use the parameter setting skip-empty-tokens="false" as shown in the following example test file: <?xml version="1.0" encoding="UTF-8"?> <configuration xmlns="http://www.watch4net.com/OutputParsingLibrary" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.watch4net.com/OutputParsingLibrary collectingconfiguration.xsd "> <max-threads>1</max-threads> <parser-config> <parser-class>com.watch4net.apg.v2.collector.plugins.outputparsing.parsing.generictext.RegexTextParser</parser-class> <tree-type>table-like-tree</tree-type> <incremental-parser>false</incremental-parser> <master-delimiter>\n</master-delimiter> <sub-delimiter skip-empty-tokens="false"> <delimiter>,</delimiter> </sub-delimiter> <parameter name="table-params"> <value>DU-CDR_</value> <value>^UNIQUE_CALL_ID,CDB_VERSION,CDB_TIMEPOINT,.*</value> </parameter> </parser-config> <data-formatter-config>com.watch4net.apg.v2.collector.plugins.textoutputcollector.formatting.RawValueFormatter</data-formatter-config> <data-handler-config>com.watch4net.apg.v2.collector.plugins.textoutputcollector.handling.DeltaRateRawValueHandler</data-handler-config> <data-config> <data-accessor>com.watch4net.apg.v2.collector.plugins.outputparsing.executing.local.FileReader</data-accessor> <stop-on-first-result>false</stop-on-first-result> <host-group-config> <custom-group> <group-name>localhost</group-name> <host-config> <host-list>localhost</host-list> </host-config> </custom-group> </host-group-config> <command-configuration> <command-list> <command type="custom">/tmp/test.csv</command> </command-list> </command-configuration> </data-config> </configuration> _________________________________________________________ For the following input file'test.csv' : UNIQUE_CALL_ID,CDB_VERSION,CDB_TIMEPOINT,CALL_REFERENCE_ID,IAM_TIMEPOINT,ACM_TIMEPOINT 1090,1,1337030221,,, 1110,1,1337030371,4fb176d20001abca,,0 1110,1,1337030371,4fb176d20001abcb,,0 1110,1,1337030312,4fb176980001abb3,0,0 1110,1,1337030312,4fb176980001abb4,0,0 1110,1,1337030347,4fb176b60001abbf,0,0 1110,1,1337030347,4fb176b60001abc0,0,0

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Unavailable

Learn More

Search:

...