NSX-v Networking and security plugin is missing in flash client after upgrading to 6.4.11

Last update date:

4/11/2024

Affected products:

NSX for vSphere

Affected releases:

6.4

Fixed releases:

No fixed releases provided.

Description:

Symptoms

Cannot access Networking and Security plugin is missing in flash client following an upgrade to NSX-v 6.4.11No functional impact because HTML5 client is still accessible.Unable to utilize SSL VPN UI which is deprecated in HTML5In the vCenter log bundle, entries similar to the below can be found in var/log/vmware/vsphere-client/logs/vsphere_client_virgo.log [2021-10-23T08:49:15.455Z] [ERROR] plugin-deploy13 org.eclipse.virgo.medic.eventlog.default DE0002E Installation of bundle 'com.vmware.vshield.plugin.common.service' version '5.1.0' failed. org.eclipse.virgo.kernel.osgi.framework.UnableToSatisfyBundleDependenciesException: Unable to satisfy dependencies of bundle 'com.vmware.vshield.plugin.common.service' at version '5.1.0': Cannot resolve: com.vmware.vshield.plugin.common.service Resolver report: An Import-Package could not be resolved. Resolver error data <Import-Package: com.vmware.vshield.sddc.model; version="0.0.0">. Caused by missing constraint in bundle <com.vmware.vshield.plugin.common.service_5.1.0> constraint: <Import-Package: com.vmware.vshield.sddc.model; version="0.0.0">

Cause

There were some unwanted SDDC references in the file "/em/maven/ui/ngc/common/vshield-common-service/src/main/resources/META-INF/MANIFEST.MF"

Resolution

Currently there is no resolution to this issue

Workaround

REST API can be used to configure SSL VPN till 6.4.12 is availablehttps://kb.vmware.com/s/article/79929

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Unavailable

Learn More

Search:

...