vRealize Network Insight shows incorrect "Host not healthy" alert

Last update date:

4/11/2024

Affected products:

NSX for vSphere

vRealize Network Insight

Affected releases:

No affected releases provided.

Fixed releases:

No fixed releases provided.

Description:

Symptoms

The below error is seen in VRNI: From the ESXi host, the following commands take more than 15 seconds to complete esxcli storage filesystem listdf -h In the NSX Manager log bundle, entries similar to the below are seen in the vsm.log file: 2021-06-28 07:39:34.959 AST WARN http-nio-127.0.0.1-7441-exec-9 VdnCommandServiceImpl:950 - - [nsxv@6876 comp="nsx-manager" subcomp="manager"] Exception thrown executing command 'esxcli storage filesystem list' on host [host-88] timeout = 15000, exception = VshieldMessagingException: core-services:2502:RPC request timed out..2021-06-28 07:39:34.960 AST ERROR http-nio-127.0.0.1-7441-exec-9 HostHealthChecker:171 - - [nsxv@6876 comp="nsx-manager" subcomp="manager"] Checking host host-88 health status failedcom.vmware.vshield.vsm.vdn.cli.exception.HostNotAccessibleException: Not able to request host host-88. Verify NSX-v is installed and configured properly on host

Cause

If there are lot of LUNs presented to the ESXi host, it is expected to see a high response time.NSX calls for “esxcli storage filesystem list” to get the host status and the timeout is 15 seconds, as the ESXi command takes longer than 15 seconds, the NSX command times out.

Resolution

Currently there is no resolution to this issue.

Workaround

Investigate if the response time on the storage side can be reduced.