4/5/2024
HCX
No affected releases provided.
No fixed releases provided.
HCX compute profile update with new datastore information will fail with error(web.log) as shown below: web.18.log.gz:2022-11-09 02:55:03.781 UTC [https-jsse-nio-127.0.0.1-8443-exec-2, Ent: HybridityAdmin, , TxId: TxId: baf15b2c-512d-44a9-b636-08632e605da9] ERROR c.v.v.h.a.i.ComputeProfileRestController- Basic validation of compute profile failed. Errors: [{"code":"E_INVALID_INPUT","message":"Computes are used by other Service Mesh SDDC1-L2E-MESH paired to same endpoint."}]. HCX Compute profile UI will report below error:
This resource is to inform about the below error and how to resolve this error. web.18.log.gz:2022-11-09 02:55:03.781 UTC [https-jsse-nio-127.0.0.1-8443-exec-2, Ent: HybridityAdmin, , TxId: TxId: baf15b2c-512d-44a9-b636-08632e605da9] ERROR c.v.v.h.a.i.ComputeProfileRestController- Basic validation of compute profile failed. Errors: [{"code":"E_INVALID_INPUT","message":"Computes are used by other Service Mesh SDDC1-L2E-MESH paired to same endpoint."}].
The issue happens due to a check for conflicting service compute such as: When using compute profiles that are sharing the same service cluster across CPs.When the same remote compute profile is in use (forming V topology).
The existing compute profile (CP) can't be updated with ANY parameters such as: Updating Datastore informationReducing or increasing CPU/MEM resources New Compute Profile can be created and updated without any issues.There won't be any impact in HCX functionality in terms of migration & network extension workflows.
None at the moment.