BugZero updated this defect 48 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
4/1/2024
Site Recovery Manager
8.x
No fixed releases provided.
1. The Update wizard spins continuously and times out with this error.2. Unable to upgrade SRM or VRMS using VAMI or CLI ERROROperation FailedFailed to retrieve update.Operation ID: a265683e-f5c5-4fe8-a819-6bc564107c8912/12/23, 9:13:42 AM -0500 /var/log/vmware/dr/drconfig.log : opID=29c24581-2463-404b-8c23-67a23b3710a8-checkForUpdates:b50b] CheckForUpdates: Update task is in progress2023-10-27T09:37:18.388+02:00 error drconfig[00950] [SRM@6876 sub=RetrieveUpdateOp opID=e0bc5a12-49d5-435f-8b6b-00183b05e2e8-checkForUpdates:8f6a] Command "/usr/bin/systemctl restart vami-sfcb" exit code: 1--> stderr:--> Job for vami-sfcb.service failed because a timeout was exceeded.--> See "systemctl status vami-sfcb.service" and "journalctl -xe" for details.--> 2023-10-27T09:37:18.391+02:00 verbose drconfig[00943] [SRM@6876 sub=PropertyProvider ctxID=6e43779a opID=e0bc5a12-49d5-435f-8b6b-00183b05e2e8-checkForUpdates:8f6a] RecordOp ASSIGN: info.progress, DrConfigConfigurationTask1. Applied change to temp map.2023-10-27T09:37:18.441+02:00 error drconfig[00950] [SRM@6876 sub=RetrieveUpdateOp opID=e0bc5a12-49d5-435f-8b6b-00183b05e2e8-checkForUpdates:8f6a] Command "/opt/vmware/bin/vamicli update --check" exit code: 1--> stderr:--> Traceback (most recent call last):--> File "/opt/vmware/bin/vamicli", line 26, in <module>--> import time--> ImportError: No module named time--> 2023-10-27T09:37:18.441+02:00 error drconfig[00950] [SRM@6876 sub=RetrieveUpdateOp opID=e0bc5a12-49d5-435f-8b6b-00183b05e2e8-checkForUpdates:8f6a] Operation failed--> (drConfig.fault.FailedToRetrieveUpdateFault) {--> faultCause = (vmodl.MethodFault) null, --> faultMessage = <unset>--> msg = ""--> }
Missing RPM package from appliance.
You cannot upgrade the appliance.
1. Revert the snapshot to base disk and delete it. 2. Take a new snapshot (without memory)3. Download python2-libs-2.7.17-7.ph3.x86_64.zip & unzip the file, move the rpm file to /tmp directory of the affected appliance using WinSCP. 4. SSH into the appliance as admin user & then login as root5. Install the rpm by running the command : rpm --force -ivh python2-libs-2.7.17-7.ph3.x86_64.rpm root@SRM [ /tmp ]# rpm --force -ivh python2-libs-2.7.17-7.ph3.x86_64.rpmVerifying... ################################# [100%]Preparing... ################################# [100%]Updating / installing... 1:python2-libs-2.7.17-7.ph3 ################################# [100%]6. Restart the vami-sfcb service : systemctl restart vami-sfcb 7. Now, you should be able to select the update source as CD-ROM and proceed with installation.