Symptoms

SDDC UI is still using the 4.x Updates interfaceIncorrect bundle or no bundle displays in LCM/UI.The environment was migrated from 3.x to 4.x/5.xThe Target upgrade version API fails with 404 error in the API Explorer. The following flags are present in the feature.properties file. cat /home/vcf/feature.propertiesfeature.lcm.store.target.version=falsefeature.vcf.isolated.wlds=false Example of 4.x Updates tab.

Purpose

To assist with make the bundle "Available" after having it downloaded via LCM.

Cause

This is known issue on 4x due to migration 3x to 4x, during migration config drift set two features in /home/vcf/ but never set it back. This will cause the 4.x to 5.x bundle to not display accurately, if the /home/vcf/feature.properties file line ---- 'feature.lcm.store.target.version' is still false.

Resolution

Removing these two lines from the feature.properties file. SSH to SDDC Manager using vcf account and su to rootEdit the file /home/vcf/feature.properties file and remove these two lines (or comment them out): feature.lcm.store.target.version=falsefeature.vcf.isolated.wlds=false Restart all of the SDDC Manager services: /opt/vmware/vcf/operationsmanager/scripts/cli/sddcmanager_restart_services.sh Login to the SDDC UI and verify the Updates interface has changed. Example of expected 5.x Updates interface,