VCDR Connectors may become unreachable after a power outage.Pinging the VCDR Connector fails.Rebooting the connector fails at the connector initialization state.Virtual Machine console of the connector appliance shows below
To help understand the cause and resolve the state
This is caused due to OVF properties not being retained as the applaince will be abruptly shut down after a power outage.
Connector is unusable and will affect recovery or snapshot schedules
Currently, there is no way to recover the appliance from debug mode. Only viable option is to re-deploy the appliance and configure it to point to same Orchestrator FQDN/IP. The Orchestrator FQDN or IP and credentials are displayed when Clicked on Deploy button in the VCDR UI.