Symptoms

Importing SRM configuration data fails with the below warnings - Create protection groups. Unable to update protection settings for datastore 'Prod-SQL'. Datastore not found.Create protection groups. Unable to update protection settings for datastore 'DB-Servers'. Datastore not found. Create protection groups. Unable to create VM protection group: 'Prod-SQL'. A specified parameter was not correct: Empty array of datastores not allowed.Create protection groups. Unable to create VM protection group: 'DB-Servers'. A specified parameter was not correct: Empty array of datastores not allowed.

Cause

SRM applies snap-xx prefix to recovered datastore names. Configuration import cannot detect these datastores until they are changed to their original names.

Impact / Risks

Configuration data import through the user interface fails partially.

Resolution

Rename all the snap-xx prefixed datastores back to their original names. Change Datastore Name

Related Information

Renaming a datastore when virtual machines are running on the datastore (1006279) - https://kb.vmware.com/s/article/1006279Change Storage Provider SettingsImport the Site Recovery Manager Configuration Data through the User Interface