BugZero updated this defect 57 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
3/23/2024
Site Recovery Manager
8.x
No fixed releases provided.
Importing SRM configuration data fails with the below warnings - Create protection groups. Unable to update protection settings for datastore 'Prod-SQL'. Datastore not found.Create protection groups. Unable to update protection settings for datastore 'DB-Servers'. Datastore not found. Create protection groups. Unable to create VM protection group: 'Prod-SQL'. A specified parameter was not correct: Empty array of datastores not allowed.Create protection groups. Unable to create VM protection group: 'DB-Servers'. A specified parameter was not correct: Empty array of datastores not allowed.
SRM applies snap-xx prefix to recovered datastore names. Configuration import cannot detect these datastores until they are changed to their original names.
Configuration data import through the user interface fails partially.
Rename all the snap-xx prefixed datastores back to their original names. Change Datastore Name
Renaming a datastore when virtual machines are running on the datastore (1006279) - https://kb.vmware.com/s/article/1006279Change Storage Provider SettingsImport the Site Recovery Manager Configuration Data through the User Interface