Operational Defect Database

BugZero updated this defect 53 days ago.

VMware | 97210

NSX Configuration Change from multi uplink to single uplink LAG shows "in progress" state

Last update date:

3/27/2024

Affected products:

NSX-T

Affected releases:

No affected releases provided.

Fixed releases:

No fixed releases provided.

Description:

Symptoms

NSX Configuration Change from multi uplink to single uplink LAG shows "in progress" state after changing the uplink profile API Call GET /api/v1/transport-nodes/<BME_TN_UUID>/state] , on Bare Metal EDGE may show a a Configuration edit failed with error. Failed to update syslog node configuration edit failed with error. failed to update syslog exporter servers failure_code:16042 Transport node Sync may be stuck with an error log in NSX Manager /var/log/proton/nsxapi ------------------------------------------ 2024-03-20T14:50:12.846Z INFO L2HostConfigTaskExecutor1 IPAMUtils 4464 FABRIC [nsx@6876 comp="nsx-manager" level="INFO" subcomp="manager"] Releasing the ip [10.235.129.8] from the ip pool [IpPool/ee3446f5-c167-465e-9547-178952eda42c]. 2024-03-20T14:50:12.847Z INFO L2HostConfigTaskExecutor1 AddressManagementServiceImpl 4464 POOL-MGMT [nsx@6876 comp="nsx-manager" level="INFO" subcomp="manager"] Attempting release of id 10.235.129.8 into pool e4e4541e-f1b0-424d-acc2-db6c5161e598 with delay 120000 2024-03-20T14:50:12.848Z INFO L2HostConfigTaskExecutor1 RangeServiceImpl 4464 POOL-MGMT [nsx@6876 comp="nsx-manager" level="INFO" subcomp="manager"] No Temporary, Permanent or deletion marker found but id 183206152 is allocated. Id must be allocated in older version-HL/GC 2024-03-20T14:50:12.848Z INFO L2HostConfigTaskExecutor1 AddressManagementServiceImpl 4464 POOL-MGMT [nsx@6876 comp="nsx-manager" level="INFO" subcomp="manager"] Id 10.235.129.8released into pool e4e4541e-f1b0-424d-acc2-db6c5161e598 2024-03-20T14:50:12.848Z INFO L2HostConfigTaskExecutor1 IPAMServiceImpl 4464 POOL-MGMT [nsx@6876 comp="nsx-manager" level="INFO" subcomp="manager"] Ip Address 10.235.129.8 is released from the range with start 10.235.129.1 and end 10.235.129.125 in the pool IpPool/ee3446f5-c167-465e-9547-178952eda42c. 2024-03-20T14:50:12.848Z ERROR L2HostConfigTaskExecutor1 TransportNodeAsyncRequestHandler 4464 FABRIC [nsx@6876 comp="nsx-manager" errorCode="MP100" level="ERROR" subcomp="manager"] TransportNodeConfigTask on host [1609265a-3f34-11eb-a7ec-0242c418909e] failed. Abort all unprocessed stages. org.corfudb.runtime.exceptions.TransactionAlreadyStartedException: An existing transaction is still in progress. TX[ae56] at org.corfudb.runtime.collections.TxnContext.txBeginInternal(TxnContext.java:90) ~[?:?] at org.corfudb.runtime.collections.TxnContext.<init>(TxnContext.java:79) ~[?:?] at com.vmware.nsx.persistence.UfoStore.tx(UfoStore.java:202) ~[?:?] at com.vmware.nsx.persistence.UfoStore.tx(UfoStore.java:186) ~[?:?] at com.vmware.nsx.management.switching.sync.host.MACAMUtils.getUfoDefaultMACAMPool(MACAMUtils.java:219) ~[?:?] at com.vmware.nsx.management.switching.sync.host.VtepPopulator.releaseVtepResources(VtepPopulator.java:1094) ~[?:?] at com.vmware.nsx.management.switching.sync.host.VtepPopulator.releaseExistingVteResources(VtepPopulator.java:1032) ~[?:?] at com.vmware.nsx.management.switching.sync.host.VtepPopulator.releaseAllResources(VtepPopulator.java:1043) ~[?:?] at com.vmware.nsx.management.switching.sync.host.VtepPopulator.releaseAllResources(VtepPopulator.java:1011) ~[?:?] at com.vmware.nsx.management.switching.sync.host.TransportNodeAsyncServiceImpl.releaseUnusedVtepResourcesAndSaveTnStateInTransaction(TransportNodeAsyncServiceImpl.java:2447) ~[?:?] at com.vmware.nsx.management.switching.sync.host.TransportNodeAsyncServiceImpl.releaseUnusedVtepResourcesAndSaveTnStateWithRetry(TransportNodeAsyncServiceImpl.java:2504) ~[?:?] at com.vmware.nsx.management.switching.sync.host.TransportNodeAsyncServiceImpl.releaseUnusedVtepResourcesAndSaveTnState(TransportNodeAsyncServiceImpl.java:2407) ~[?:?] ---------------------------

Cause

This is a known issue in 3.2.0 and up to 3.2.2.3

Impact / Risks

Previous VTEP is not removed from the bond created by LAG and may cause data forwarding issue

Resolution

Issue is fixed in upcoming version 3.2.4 and in 4.1.2 and above

Workaround

No workaround available