SD-WAN: BGP never sends keep alives if timers are blank in VCO UI

Last update date:

3/30/2024

Affected products:

SD-WAN

SD-WAN by VeloCloud

Affected releases:

No affected releases provided.

Fixed releases:

No fixed releases provided.

Description:

Symptoms

If a user configures the BGP keep alive and hold timers as blank in the Orchestrator UI, the peer device BGP state will remain up, however once the edge restarts, the BGP adjacency between the edge and the peer will not come back up.

Cause

This is caused by known issue #129694This is an issue with Orchestrator UI Validation.The Orchestrator should not allow blank values as these are sent as an empty string.The expected behavior for the UI is to have default values in these timers and if these are deleted with no replacement value and saved, the Orchestrator should throw an error and require an actual integer value.

Resolution

This issue is resolved in VMware SD-WAN Orchestrator Version 5.2.3 (R5230-20240315-GA).For more information please see VMware SD-WAN Software Upgrade FAQs

Workaround

Instead of leaving these fields blank in UI, configure some values.The default values are 60s for keep alive timer and 180s for hold timer.