TKGi Management Console filed with error "Input Validation failed Validation errors found IP xxxxx in floating_ip_range is already in use"

Last update date:

4/4/2024

Affected products:

Tanzu Kubernetes Grid Integrated Edition

Affected releases:

1.15

Fixed releases:

No fixed releases provided.

Description:

Symptoms

When trying to replace TKGi API certificate in TKGi Management Console according to KB https://kb.vmware.com/s/article/89807 , Issue in Apply changes to Management Console Configuration due to incorrect floating IP range set in TKGi Configuration Error shown as follows:

Cause

Incorrect TKGi Management Console Configuration floating IP set

Impact / Risks

Unable to Generate Configuration and Apply Changes in TKGi Management Console

Resolution

Fix floating IP range in TKGi MC with correct start IP and End IP as follows: Please make sure that the summary page in the TKGI MC is normal before changing the value of floating_ips_range as in screenshot below:​ Steps for changing floating IP range in TKGi MC as follows: ssh to the TKGI MC VM.`curl -k -u root -H “Content-Type: application/json” https://localhost/api/v1/deployment/manifest | jq -r . >manifest.json`update floating_ips_range to expected value.`curl -k -u root -H “Content-Type: application/json” -X POST -d @manifest.json https://localhost/api/v1/deployment` After changing the IP using API POST, Confirm in TKGi management console that IP is changed Generate Configuration and Apply required changes in TKGi Management Console Configuration Tab

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Unavailable

Learn More

Search:

...