TKGi cluster creation failed with error in finding network 'pks-xxxxx' after multiple retries

Last update date:

4/5/2024

Affected products:

Tanzu Kubernetes Grid Integrated Edition

Affected releases:

1.15

Fixed releases:

No fixed releases provided.

Description:

Symptoms

Trying to create new TKGi cluster failing with error finding network "pks-xxx' after multiple retries"

Cause

Connection issue between vCenter and NSX-T Manager side due to Thumbprint Mismatch

Impact / Risks

Unable to create new TKGi Clusters

Resolution

Confirm the CM thumbprint in vCenter and NXS-T side as per below steps: From root of an SSH session to the vCenter run the following command: openssl x509 -in /etc/vmware-vpx/ssl/rui.crt -fingerprint -sha256 -noout The output should look similar to the following: Next from the NSX-T UI complete the below: Browse to: System > Fabric > Computer Managers > Select CM > Edit Confirm that both Thumbprints are the sameReplace the incorrect Thumbprint in NSX-T Compute Manager with the output from vCenter