4/10/2024
NSX
4.1
No fixed releases provided.
NSX all versionsEdge datapath stops functioning as expected and stops forwarding trafficNSX Edge syslog has a log signature similar to this example 2024-02-24T13:37:03.663Z Edge 07b7117dfd5a 3774 - - 2024-02-24T13:37:03Z datapathd 16336 epconn-services tname="dp-ipc31" [ERROR] Failed to operate: Processing request from NSXA (-22) errorCode="EDG0000005"2024-02-24T13:37:03.221Z Edge datapath-systemd-helper 16235 - - 2024-02-24T13:37:03Z datapathd 16336 epconn-services tname="dp-ipc31" [ERROR] Failed to operate: Processing request from NSXA (-22) errorCode="EDG0000005"
In very rare cases, the Edge may stop forwarding traffic due to epconn connection getting closed to NSXA.
This is known issue impacting NSX.
Reboot the impacted Edge.