Description:

Symptoms

NSX all versionsEdge datapath stops functioning as expected and stops forwarding trafficNSX Edge syslog has a log signature similar to this example 2024-02-24T13:37:03.663Z Edge 07b7117dfd5a 3774 - - 2024-02-24T13:37:03Z datapathd 16336 epconn-services tname="dp-ipc31" [ERROR] Failed to operate: Processing request from NSXA (-22) errorCode="EDG0000005"2024-02-24T13:37:03.221Z Edge datapath-systemd-helper 16235 - - 2024-02-24T13:37:03Z datapathd 16336 epconn-services tname="dp-ipc31" [ERROR] Failed to operate: Processing request from NSXA (-22) errorCode="EDG0000005"

Cause

In very rare cases, the Edge may stop forwarding traffic due to epconn connection getting closed to NSXA.

Resolution

This is known issue impacting NSX.

Workaround

Reboot the impacted Edge.