Operational Defect Database

BugZero found this defect 1150 days ago.

WatchGuard Technologies | kA10H000000Xe7BSAS

Host range BOVPN does not pass traffic beyond first /24 subnet

Last update date:

3/26/2021

Affected products:

Firebox M200

Firebox M300

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M290

Firebox M390

Firebox M400

Firebox M500

Firebox M440

Affected releases:

All

Fireware

12.x

12.6.x

Fixed releases:

v12.7.1

Description:

Issue

In Fireware 12.6.x, host range BOVPNs fail to pass traffic when the range of IP addresses exceeds a /24 subnet, such as 192.168.0.0 - 192.168.10.255. In this example, only traffic to 192.168.0.0/24 passes through the VPN.

Workaround/Solution

Use smaller host ranges or subnets instead (maximum /24).

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Resolved

Learn More

Search:

...