Operational Defect Database

BugZero found this defect 1399 days ago.

WatchGuard Technologies | kA10H000000bp3lSAA

TDR Host Sensor Enforcement requirements are not checked for Firebox-DB users with login limits enabled

Last update date:

7/21/2020

Affected products:

Firebox M200

Firebox M300

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M290

Firebox M390

Firebox M400

Firebox M500

Firebox M440

Affected releases:

All

Fireware

12.x

12.5.x

Fixed releases:

v12.6.3

Description:

Issue

When the Enable login limits for each user or group check box is enabled for a Firebox-DB user account, TDR Host Sensor Enforcement requirements are not checked for that user when they log in to Mobile VPN with SSL.

Workaround/Solution

No workaround currently exists for this issue. To enforce the requirements, you can disable login limits for the affected user.