WSM 12.6.2 fails to save configuration if DVCP Tunnel name is more than 42 characters

Last update date:

9/3/2020

Affected products:

Firebox M200

Firebox M300

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M290

Firebox M390

Firebox M400

Firebox M500

Firebox M440

Affected releases:

All

Fireware

12.x

12.6.x

Fixed releases:

v12.6.2 Update 2

Description:

Issue

In WSM 12.6.2, Policy Manager fails to save a configuration to a Firebox that runs Fireware v12.5.4 or lower if a DVCP tunnel name is more than 42 characters. DVCP tunnel names are generated in the format: [Device Name].[VPN Resource Name].x

Workaround/Solution

To work around this issue, decrease the length of the VPN resource name. This is the simplest way to update multiple tunnels.