BugZero found this defect 1354 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
9/3/2020
Firebox M200
Firebox M300
Firebox M270
Firebox M370
Firebox M470
Firebox M570
Firebox M670
Firebox M290
Firebox M390
Firebox M400
Firebox M500
Firebox M440
All
Fireware
12.x
12.6.x
v12.6.2 Update 2
In WSM 12.6.2, Policy Manager fails to save a configuration to a Firebox that runs a Fireware version other than v12.5.5 or v12.6.2 if BOVPN over TLS is configured.When you try to save the configuration, this error message appears: The OS version of the Firebox or configuration file does not support these string values due to character set or string length.
Use Fireware Web UI to save the configuration to the Firebox. Alternatively, upgrade the Firebox to Fireware v12.5.5 or v12.6.2.