Operational Defect Database

BugZero found this defect 1354 days ago.

WatchGuard Technologies | kA10H000000bpMOSAY

WSM v12.6.2 fails to save configuration if BOVPN over TLS is configured

Last update date:

9/3/2020

Affected products:

Firebox M200

Firebox M300

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M290

Firebox M390

Firebox M400

Firebox M500

Firebox M440

Affected releases:

All

Fireware

12.x

12.6.x

Fixed releases:

v12.6.2 Update 2

Description:

Issue

In WSM 12.6.2, Policy Manager fails to save a configuration to a Firebox that runs a Fireware version other than v12.5.5 or v12.6.2 if BOVPN over TLS is configured.When you try to save the configuration, this error message appears: The OS version of the Firebox or configuration file does not support these string values due to character set or string length.

Workaround/Solution

Use Fireware Web UI to save the configuration to the Firebox. Alternatively, upgrade the Firebox to Fireware v12.5.5 or v12.6.2.

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Resolved

Learn More