Cannot set OS compatibility to v12.5.x if an ICMPv6 custom policy exists in v12.6.x configuration

Last update date:

9/28/2020

Affected products:

Firebox M200

Firebox M300

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M290

Firebox M390

Firebox M400

Firebox M500

Firebox M440

Affected releases:

All

Fireware

12.x

12.6.x

Fixed releases:

All

Description:

Issue

In WSM v12.6.2 U2, if your configuration includes an ICMPv6 custom policy, and you change the OS Compatibility setting to v12.5.x, this error appears: Fireware OS lower than v12.6.2 does not support the ICMPv6 custom protocol.

Workaround/Solution

Remove the ICMPv6 custom policy.Change the OS Compatibility setting.Save the configuration as the older version.Add the ICMPv6 custom policy back to the configuration.