BugZero found this defect 1326 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
10/2/2020
Firebox M200
Firebox M300
Firebox M270
Firebox M370
Firebox M470
Firebox M570
Firebox M670
Firebox M290
Firebox M390
Firebox M400
Firebox M500
Firebox M440
All
Fireware
12.x
12.6.x
All
When the Force randomization for images (Mandatory ASLR) setting is set to On by default in the Windows Security App & Browser Control settings, you see an error message like this when you try to install WSM: Runtime error (at - 1:0); cannot import dll:c:\users\....\is-NKUU.tmp\IssProc.dll
Open the Windows Security App & Browser Control settings.In the Exploit protection section, click Exploit protection settings.From the Force randomization for images (Mandatory ASLR) drop-down list, select Use default (Off).Install WSM.Change the Force randomization for images (Mandatory ASLR) setting back to its original value. Note: If this workaround does not resolve the issue, it might be caused by something else. For more information, see issproc.dll error when installing WatchGuard System Manager.