Application Control category action changes to Drop after upgrade to Fireware v12.6.2

Last update date:

11/6/2020

Affected products:

Firebox T20

Firebox T40

Firebox T80

Affected releases:

All

Fireware

12.x

12.6.x

Fixed releases:

All

Description:

Issue

After you upgrade a T20, T40, or T80 device from Fireware v12.6.1 to Fireware v12.6.2, the action for an Application Control category might change from Allow to Drop. This can cause the Firebox to drop connections for applications that were not configured to Drop before the upgrade.

Workaround/Solution

After you upgrade the device, review the Application Control actions configured in your policies and update any actions that changed.