Operational Defect Database

BugZero found this defect 1285 days ago.

WatchGuard Technologies | kA10H000000bpu6SAA

Interfaces with fixed link speeds change to 10 Mbps Half Duplex after upgrade from Fireware v12.5.4 to v12.6.2

Last update date:

11/11/2020

Affected products:

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Affected releases:

All

Fireware

12.x

12.6.x

Fixed releases:

All

Description:

Issue

After you upgrade an M270 Firebox from Fireware v12.5.4 to v12.6.2, if the Firebox had an interface with a fixed link speed value, such as 1000 Mbps Full Duplex, the interface link speed value might change to 10 Mbps Half Duplex.

Workaround/Solution

Change the value of the Link Speed setting to Auto Negotiate, then change it back to the original value.

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?