Operational Defect Database

BugZero found this defect 1284 days ago.

WatchGuard Technologies | kA10H000000bpv4SAA

Application Control category actions not applied correctly on 12.5.x Firebox fully managed by Management Server 12.6.x

Last update date:

11/12/2020

Affected products:

Firebox M200

Firebox M300

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M290

Firebox M390

Firebox M400

Firebox M500

Firebox M440

Affected releases:

All

Fireware

12.x

12.5.x

12.6.x

Fixed releases:

All

Description:

Issue

Application Control category actions might not function as configured on a Firebox that runs Fireware v12.5.x and is fully managed by Management Server v12.6.x. This is because of a category ID change in Fireware v12.6. To verify whether you have this issue, compare your Application Control settings to the applied actions in the Application Control traffic logs.

Workaround/Solution

Change the Firebox management mode to Basic.Connect directly to Fireware Web UI.To update the Application Control configuration with the correct category IDs, edit each configured category action, verify the actions, and save.