Firebox M200
Firebox M300
Firebox M270
Firebox M370
Firebox M470
Firebox M570
Firebox M670
Firebox M290
Firebox M390
Firebox M400
Firebox M500
Firebox M440
All
Fireware
12.x
12.6.x
All
If the primary RADIUS server is down, RADIUS failover does not work when MFA is used because the backup RADIUS server times out after 5 seconds and is marked as dead.
Remove the backup RADIUS server and then configure the backup as the primary RADIUS server.