Operational Defect Database

BugZero found this defect 1188 days ago.

WatchGuard Technologies | kA10H000000bqRKSAY

Backup RADIUS server times out after 5 seconds

Last update date:

2/16/2021

Affected products:

Firebox M200

Firebox M300

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M290

Firebox M390

Firebox M400

Firebox M500

Firebox M440

Affected releases:

All

Fireware

12.x

12.6.x

Fixed releases:

All

Description:

Issue

If the primary RADIUS server is down, RADIUS failover does not work when MFA is used because the backup RADIUS server times out after 5 seconds and is marked as dead.

Workaround/Solution

Remove the backup RADIUS server and then configure the backup as the primary RADIUS server.

Additional Resources / Links

Share: