FireCluster fails over unexpectedly when you rename monitored network interfaces

Last update date:

2/16/2023

Affected products:

Firebox M200

Firebox M300

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M290

Firebox M390

Firebox M400

Firebox M500

Firebox M440

Affected releases:

All

Fireware

11.x

11.1.x

11.10.x

11.10

11.10.1

11.10.2

11.10.3

11.10.4

11.10.5

11.10.6

Fixed releases:

v12.9.3

Description:

Issue

When you rename a network interface, VLAN interface, or LAG interface that the FireCluster configuration monitors, the health index of the primary cluster member drops, which causes a failover event.

Workaround/Solution

Before you rename the interface, clear the option to monitor the interface link in the FireCluster configuration. Renaming an unmonitored interface does not drop the FireCluster health index or cause a failover event. After you rename the interface, you can re-enable link monitoring in the FireCluster configuration.