Description:

Issue

When you connect to a Firebox with WatchGuard System Manager from a Link Aggregation interface, Policy Manager fails to open, with an error message that looks like this:An error occurred while downloading configuration from the Firebox 10.0.1.1.Failed to read servers response: Invalid TLS padding data.

Workaround/Solution

Connect to the Firebox from a different network interface, or use the Web UI to manage the device.