BugZero found this defect 3359 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
3/9/2015
Firebox M200
Firebox M300
Firebox M270
Firebox M370
Firebox M470
Firebox M570
Firebox M670
Firebox M290
Firebox M390
Firebox M400
Firebox M500
Firebox M440
All
Fireware
11.x
11.2.x
11.3.x
11.3.1
11.3.2
11.3.3
11.3.4
11.3.5
11.3.6
11.4.x
All
When you restore the backup for a Management Server on a Windows Server 2012 R2 computer, the server will fail to start.
Use these steps to resolve this issue: Open the Windows Desktop.Right-click the Windows Start Button and select Command Prompt (Admin) The administrator command prompt appears.Browse to the folder Program Files <x86>\WatchGuard\wsm11\wmserver\bin\ If you installed WatchGuard System Manager to a different location, browse to the \bin\ folder at that location.Run the command wmserver.exe -configstart