Operational Defect Database

BugZero found this defect 2749 days ago.

WatchGuard Technologies | kA10H000000g3OnSAI

Policy-Based Routing disregards failover configuration when configured with WebUI

Last update date:

11/8/2016

Affected products:

Firebox M200

Firebox M300

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M290

Firebox M390

Firebox M400

Firebox M500

Firebox M440

Affected releases:

All

Fireware

11.x

11.11.x

11.11

11.11.1

11.11.2

11.11.4

Fixed releases:

All

Description:

Issue

If you use Fireware Web UI to configure Policy-Based Routing (PBR), the Firebox will allow connections to fail over to other external interfaces when the interfaces are not selected for PBR failover.The Firebox will use the correct interfaces for traffic as long as they are marked as available.

Workaround/Solution

This issue does not occur if you configure Policy-Based Routing with Policy Manager.

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Resolved

Learn More