Operational Defect Database

BugZero found this defect 2800 days ago.

WatchGuard Technologies | kA10H000000g3OqSAI

Server Load Balancing fails on Firebox T30 and T50 devices

Last update date:

9/27/2016

Affected products:

Firebox T30

Firebox T50

Affected releases:

All

Fireware

11.x

11.11.x

11.11

11.11.1

11.11.2

Fixed releases:

All

Description:

Issue

If you configure Server Load Balancing on a Firebox T30, T50, or T70 device, the Firebox fails to pass any traffic for a policy that includes a Server Load Balancing action.When you save a configuration to the Firebox with a Server Load Balancing action in it, the log file shows a message that looks like this:firewall Feature key does not support the feature Server Load BalanceFirebox T10 devices do not support the Server Load Balancing feature and are not affected by this issue.

Workaround/Solution

No workaround exists at this time.

Additional Resources / Links

Share:

BugZero® Risk Score