BugZero found this defect 2800 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
9/27/2016
Firebox T30
Firebox T50
All
Fireware
11.x
11.11.x
11.11
11.11.1
11.11.2
All
If you configure Server Load Balancing on a Firebox T30, T50, or T70 device, the Firebox fails to pass any traffic for a policy that includes a Server Load Balancing action.When you save a configuration to the Firebox with a Server Load Balancing action in it, the log file shows a message that looks like this:firewall Feature key does not support the feature Server Load BalanceFirebox T10 devices do not support the Server Load Balancing feature and are not affected by this issue.
No workaround exists at this time.