BugZero found this defect 2754 days ago.
Data sources
All data on this page is proprietary to BugZero® or gathered from public sources
11/16/2016
Firebox M200
Firebox M300
Firebox M270
Firebox M370
Firebox M470
Firebox M570
Firebox M670
Firebox M290
Firebox M390
Firebox M400
Firebox M500
Firebox M440
All
Fireware
11.x
11.12.x
11.12
12.x
12.0.x
12.1.x
12.1
12.1.1
12.1.3
12.10.x
All
If your FireCluster has an external interface configured with DHCP, active connections that use that external interface will be removed from the connection table when the DHCP server assigns a new IP address, even if the new IP address is exactly the same as the previous IP address.
To avoid this issue, make sure your FireCluster only renews its IP address during non-production hours, or configure the external interface with a static IP address instead of DHCP.