Operational Defect Database

BugZero found this defect 1860 days ago.

WatchGuard Technologies | kA10H000000g3SSSAY

Cannot use FQDN in Management Server templates with WSM v12.4

Last update date:

4/17/2019

Affected products:

Firebox M200

Firebox M300

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M290

Firebox M390

Firebox M400

Firebox M500

Firebox M440

Affected releases:

All

Fireware

12.x

12.4.x

Fixed releases:

All

Description:

Issue

If you use WatchGuard System Manager v12.4 and you try to modify the source or destination of a policy in a Management Server template to use a FQDN (Fully Qualified Domain Name), the FQDN entry is not correctly saved or applied.

Workaround/Solution

If you want to use FQDNs in your Management Server template, you must use WatchGuard System Manager > Management Server v12.3.x or lower until this issue is resolved.

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Resolved

Learn More