Operational Defect Database

BugZero found this defect 1853 days ago.

WatchGuard Technologies | kA10H000000g3SkSAI

Interfaces added after you enable DNS Forwarding are not included in DNS forwarding configuration

Last update date:

4/23/2019

Affected products:

Firebox M200

Firebox M300

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M290

Firebox M390

Firebox M400

Firebox M500

Firebox M440

Affected releases:

All

Fireware

12.x

12.0.x

12.1.x

12.1

12.1.1

12.1.3

12.10.x

12.2.x

12.3.x

12.4.x

Fixed releases:

All

Description:

Issue

If you configure a new interface on a Firebox with DNS Forwarding set to Listen on all Trusted, Optional, and Custom interfaces, the Firebox does not include the new interface in the DNS forwarding configuration. As a result, DNS requests to the Firebox from the new interface are denied as unhandled.

Workaround/Solution

In either Policy Manager or Fireware Web UI, select Listen only on selected interfaces in the DNS Forwarding drop-down menu. After you do this, select Listen on all Trusted, Optional, and Custom interfaces.

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Open

Learn More

Search:

...