5/29/2019
Firebox M200
Firebox M300
Firebox M270
Firebox M370
Firebox M470
Firebox M570
Firebox M670
Firebox M290
Firebox M390
Firebox M400
Firebox M500
Firebox M440
All
Fireware
12.x
12.4.x
All
After you fail over, then fail back a FireCluster, the FireCluster master might fail to set a default route for traffic to the Internet. Because of this, access to the Internet through the FireCluster could fail after the failback. To confirm that this is the issue, review the current active routes on the Firebox. For instructions, see Read the Firebox Route Tables.
Before you fail back to the original cluster master, you must reboot the cluster master to avoid this issue.