Operational Defect Database

BugZero found this defect 1817 days ago.

WatchGuard Technologies | kA10H000000g3SuSAI

FireCluster cannot route traffic to Internet after cluster failover and failback

Last update date:

5/29/2019

Affected products:

Firebox M200

Firebox M300

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M290

Firebox M390

Firebox M400

Firebox M500

Firebox M440

Affected releases:

All

Fireware

12.x

12.4.x

Fixed releases:

All

Description:

Issue

After you fail over, then fail back a FireCluster, the FireCluster master might fail to set a default route for traffic to the Internet. Because of this, access to the Internet through the FireCluster could fail after the failback. To confirm that this is the issue, review the current active routes on the Firebox. For instructions, see Read the Firebox Route Tables.

Workaround/Solution

Before you fail back to the original cluster master, you must reboot the cluster master to avoid this issue.

Additional Resources / Links

Share:

BugZero® Risk Score

What's this?

Coming soon

Status

Resolved

Learn More