Branch Office VPNs configured to use Modem Failover fail to connect after Modem Failover disabled on Firebox

Last update date:

3/6/2017

Affected products:

Firebox M200

Firebox M300

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M290

Firebox M390

Firebox M400

Firebox M500

Firebox M440

Affected releases:

All

Fireware

11.x

11.12.x

11.12

11.12.1

11.12.2

Fixed releases:

All

Description:

Issue

If your Firebox has a Branch Office VPN configured that includes Modem Failover in the Branch Office Gateway configuration, the Branch Office VPN will fail if you disable Modem Failover for the Firebox.

Workaround/Solution

You must disable Modem Failover in each configured Branch Office VPN before you disable Modem Failover for the Firebox.