Operational Defect Database

BugZero found this defect 1964 days ago.

WatchGuard Technologies | kA10H000000g3U1SAI

VLANs fail after you migrate configuration to a Firebox with fewer interfaces

Last update date:

1/2/2019

Affected products:

Firebox M200

Firebox M300

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M290

Firebox M390

Firebox M400

Firebox M500

Firebox M440

Affected releases:

All

Fireware

12.x

12.0.x

12.1.x

12.1

12.1.1

12.1.3

12.10.x

12.2.x

12.3.x

12.4.x

Fixed releases:

All

Description:

Issue

If you migrate your configuration to a Firebox with fewer interfaces than the original, configured VLANs will fail to pass traffic. When this occurs, the interfaces are marked as down in Firebox System Manager > Status Report.

Workaround/Solution

To resolve this issue, you must change the name of each configured VLAN to a different name.