WatchGuard Technologies | kA10H000000g3UHSAY

Kernel crash occurs if a BOVPN virtual interface has an external interface configured with an MTU smaller than 1304

Last update date:

4/6/2017

Affected products:

Firebox M200

Firebox M300

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M290

Firebox M390

Firebox M400

Firebox M500

Firebox M440

Affected releases:

All

Fireware

11.x

11.10.x

11.10

11.10.1

11.10.2

11.10.3

11.10.4

11.10.5

11.10.6

11.10.7

Fixed releases:

All

Description:

Issue

In Fireware v11.12.1 and earlier, a kernal crash occurs if both of these conditions are met: A BOVPN virtual interface is configured.The external interface used by the BOVPN virtual interface is configured with an MTU smaller than 1304.

Workaround/Solution

Fireware v11.12.1 or earlier In the Advanced settings for the external interface, specify an MTU that is greater than 1304. Fireware v11.12.2 or higher No workaround is required after you upgrade to Fireware v11.12.2.