4/6/2017
Firebox M200
Firebox M300
Firebox M270
Firebox M370
Firebox M470
Firebox M570
Firebox M670
Firebox M290
Firebox M390
Firebox M400
Firebox M500
Firebox M440
All
Fireware
11.x
11.10.x
11.10
11.10.1
11.10.2
11.10.3
11.10.4
11.10.5
11.10.6
11.10.7
All
In Fireware v11.12.1 and earlier, a kernal crash occurs if both of these conditions are met: A BOVPN virtual interface is configured.The external interface used by the BOVPN virtual interface is configured with an MTU smaller than 1304.