WSM Quick Setup Wizard cannot save configuration to Firebox in Recovery Mode

Last update date:

3/7/2017

Affected products:

Firebox M200

Firebox M300

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M290

Firebox M390

Firebox M400

Firebox M500

Firebox M440

Affected releases:

All

Fireware

11.x

11.12.x

11.12

11.12.1

Fixed releases:

All

Description:

Issue

If you reset your Firebox in recovery mode, the Quick Setup Wizard launched from WatchGuard System Manager will fail to save your configuration to the Firebox.

Workaround/Solution

After the Quick Setup Wizard completes, the Firebox will have a default configuration.To configure the Firebox, you must physically connect your management workstation to Firebox Eth 1, and use WatchGuard System Manager to connect to the host IP address 10.0.1.1. Your management workstation must have an IP address within the 10.0.1.0/24 subnet.The status passphrase will be the default passphrase readonly. The admin passphrase will be the default passphrase readwrite.