3/7/2017
Firebox M200
Firebox M300
Firebox M270
Firebox M370
Firebox M470
Firebox M570
Firebox M670
Firebox M290
Firebox M390
Firebox M400
Firebox M500
Firebox M440
All
Fireware
11.x
11.12.x
11.12
11.12.1
All
If you reset your Firebox in recovery mode, the Quick Setup Wizard launched from WatchGuard System Manager will fail to save your configuration to the Firebox.
After the Quick Setup Wizard completes, the Firebox will have a default configuration.To configure the Firebox, you must physically connect your management workstation to Firebox Eth 1, and use WatchGuard System Manager to connect to the host IP address 10.0.1.1. Your management workstation must have an IP address within the 10.0.1.0/24 subnet.The status passphrase will be the default passphrase readonly. The admin passphrase will be the default passphrase readwrite.