Operational Defect Database

BugZero found this defect 4457 days ago.

WatchGuard Technologies | kA10H000000g3YPSAY

Mobile VPN with SSL connections fail if data channel set to TCP port 80

Last update date:

6/23/2016

Affected products:

Firebox M200

Firebox M300

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M290

Firebox M390

Firebox M400

Firebox M500

Firebox M440

Affected releases:

All

Fireware

11.x

11.1.x

11.10.x

11.10

11.10.1

11.10.2

11.10.3

11.10.4

11.10.5

11.10.6

Fixed releases:

All

Description:

Issue

In the Mobile VPN with SSL Advanced configuration tab, you have the option to change the data channel used to send data after a VPN connection is established. If you select TCP port 80 as the data channel port, after you save this change to your XTM device all SSL VPN client connections fail.

Workaround/Solution

You must select a port other than 80 for Mobile VPN with SSL.