WatchGuard Technologies | kA10H000000g3bOSAQ

Management Server fails to lock configuration when AD user connects to device

Last update date:

10/15/2018

Affected products:

Firebox M200

Firebox M300

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M290

Firebox M390

Firebox M400

Firebox M500

Firebox M440

Affected releases:

All

Fireware

12.x

12.0.x

12.1.x

12.1

12.1.1

12.1.3

12.2.x

Fixed releases:

All

Description:

Issue

If you connect to Management Server with an Active Directory authentication user, the Management Server will not lock the configuration of Fireboxes you connect to. Because of this, multiple users could connect to a particular Firebox at the same time and one user could unexpectedly overwrite the configuration changes made by another user.

Workaround/Solution

No workaround exists at this time.