Operational Defect Database

BugZero found this defect 1993 days ago.

WatchGuard Technologies | kA10H000000g3bQSAQ

Gateway AV does not use the configured Scan size limit

Last update date:

12/4/2018

Affected products:

Firebox M200

Firebox M300

Firebox M270

Firebox M370

Firebox M470

Firebox M570

Firebox M670

Firebox M290

Firebox M390

Firebox M400

Firebox M500

Firebox M440

Affected releases:

All

Fireware

12.x

12.0.x

Fixed releases:

All

Description:

Issue

In Fireware v12.0, Gateway AV does not use the Scan size limit configured in a proxy action. It uses a 5 MB or 10 MB scan limit, based on the available RAM.

Workaround/Solution

Upgrade to Fireware v12.0.1 or higher. The default and maximum scan size limits changed in Fireware v12.0.1. When you upgrade Fireware OS, the Gateway AntiVirus Scan size limit does not automatically change to the new default. We recommend that you update the Scan size limit to the default value for your Firebox model. For more information, see About Gateway AntiVirus Scan Limits in Fireware Help.